Configuring Quality of Service
338
ProSafe M5300 Switch
To configure CoS Queue Drop Precedence Configuration settings:
1. From the Interface menu, select the interface to configure.
2. In the Queue ID field, select a queue to associate with the selected interface.
3. From the Drop Precedence Level field, select a drop precedence level.
4. In the WRED Minimum Threshold field, specify the weighted RED minimum queue
threshold below which no packets are dropped for the current drop precedence level. Default
values are:
40/30/20/100 for Drop Precedence Levels 1/2/3/4 on QueueID 0
40/30/20/100 for Drop Precedence Levels 1/2/3/4 on QueueID 1
40/30/20/100 for Drop Precedence Levels 1/2/3/4 on QueueID 2
40/30/20/100 for Drop Precedence Levels 1/2/3/4 on QueueID 3
40/30/20/100 for Drop Precedence Levels 1/2/3/4 on QueueID 4
40/30/20/100 for Drop Precedence Levels 1/2/3/4 on QueueID 5
40/30/20/100 for Drop Precedence Levels 1/2/3/4 on QueueID 6
Valid Range is (0 to 100) in sixteenths of the overall device queue size.
5. In the WRED Maximum Threshold field, specify the weighted RED maximum queue
threshold above which all packets are dropped for the current drop precedence level. Default
values are:
100/90/80/100 for Drop Precedence Levels 1/2/3/4 on QueueID 0
100/90/80/100 for Drop Precedence Levels 1/2/3/4 on QueueID 1
100/90/80/100 for Drop Precedence Levels 1/2/3/4 on QueueID 2
100/90/80/100 for Drop Precedence Levels 1/2/3/4 on QueueID 3
100/90/80/100 for Drop Precedence Levels 1/2/3/4 on QueueID 4
100/90/80/100 for Drop Precedence Levels 1/2/3/4 on QueueID 5
100/90/80/100 for Drop Precedence Levels 1/2/3/4 on QueueID 6
Valid Range is (0 to 100) in sixteenths of the overall device queue size.
6. In the WRED Drop Probability field, specify the packet drop probability for the current drop
precedence level. Default value is 10. Valid Range is (0 to 100).